Pressure Reducing Valve GP-1000SS | Yoshitake Inc.

Product Search

Pressure Reducing Valve

GP-1000SS

* Wetted parts: Stainless steel
* Pilot operated piston type
* Superior durability
* Stable performance
* Valve leakage meets ANSI class IV
* High reduction ratio (20:1)
Image:GP-1000SS

Feature Piston type / Wetted parts: Stainless steel / Flanged
Type Pilot operated piston type
Specifications Application Steam
Inlet pressure 0.1 - 1.0MPa
Reduced pressure 0.05 - 0.9MPa
Connection JIS 10K FF flanged
Adjustable reduced pressure 90% or less of the inlet pressure(gauge pressure)
Min. differential pressure 0.05MPa
Max. pressure reduction ratio 20:1
Max. temperature 220 degree(C)
Material Body Stainless steel
Main valve & seat Stainless steel
Pilot valve & seat Stainless steel
Piston & Cylinder Stainless steel
Remarks

إلى أعلى هذه الصفحة


Enter a value in the following field for a calculation of flow rate.
Application:
Inlet pressure: MPa Reduced pressure: MPa
* Whenever you change values, be sure to click on the "Calculate" button.
Capacity may vary according to the installation condition.
Please contact the international Dept. when placing an order.


Size L (mm) H (mm) Weight (kg) Cv value
15A(1/2) 150 288 8.3 1
20A(3/4) 155 288 8.8 2.3
25A(1) 160 303 10.5 4
32A(1 1/4) 190 326 14.8 6.5
40A(1 1/2) 190 326 16.3 9
50A(2) 220 350 20.8 16
65A(2 1/2) 245 360 27.4 25
80A(3) 290 407 38.8 36
100A(4) 330 454 54.5 64


[About flow rate]
Please refer to the nominal size selection chart when the inlet pressure is 0.6 MPa or more and the pressure reduction ratio exceeds 10:1.

Selection data: Specifications Selection Chart  Nominal Size Selection Chart (For Steam) 