Air Operated Valve/Control Valve
CT-100
* Versatile application with equal percentage characteristics and 50:1 rangeability.
* Stainless steel trim provides excellent sealing (ANSI Class IV seat leakage).
* Easy to service.

Yoshitake
Air Operated Valve/Control Valve
* Versatile application with equal percentage characteristics and 50:1 rangeability.
* Stainless steel trim provides excellent sealing (ANSI Class IV seat leakage).
* Easy to service.

| Type | Globe type single seated control valve | |
|---|---|---|
| Specifications | Product type | Control valve |
| Nominal size | 15A (1/2") - 65A (2-1/2") | |
| Application | Steam, air, water, oil and other non-dangerous fluids | |
| End connection | JIS 10KRF/20KRF, ASME Class 150/300 or EN PN16/25 flanged | |
| Max. pressure | 2.5 MPa (*1) | |
| Max. working differential pressure | Please refer to the Pressure–Temperature Rating Table.*1 | |
| Working temperature | -5 to 250℃ (no freezing) *1 | |
| Seat leakage | Cv 0.01% or less (ANSI Class IV)*2 | |
| Actuator type | Pneumatic single-acting diaphragm actuator | |
| Action | Reverse (normally close) or Direct (normally open) | |
| Air pressure | 0.1-0.3MPa *3 | |
| Material | Body | Ductile cast iron |
| Valve and valve seat | Stainless steel | |
| Gasket | Graphite + Stainless steel | |
| Gland packing | Graphite | |
*1 The relation between maximum pressure and maximum temperature is according to the table below.
*2 Please refer to the table on the next page for the rated CV values.
*3 Supply a pressure of 0.4 to 0.7 MPa to the positioner (optional accessory regulator) to ensure full travel.
| Size | L | H | A | Stroke | Weight (With E/P positioner) E/P positioner) | Weight (With smart positioner) |
|---|---|---|---|---|---|---|
| 15A(1/2") | 130 | 464 | 290 | 25 | 23 | 24 |
| 20A(3/4") | 150 | 464 | 290 | 25 | 24 | 25 |
| 25A(1") | 160 | 464 | 290 | 25 | 25 | 26 |
| 32A(1-1/4") | 180 | 465 | 290 | 25 | 27 | 28 |
| 40A(1-1/2") | 200 | 468 | 290 | 25 | 29 | 30 |
| 50A(2") | 230 | 576 | 360 | 40 | 42 | 43 |
| Size | L | H | A | Stroke | Weight (With E/P positioner) | Weight (With smart positioner) |
|---|---|---|---|---|---|---|
| 15AA(1/2") | 184 | 464 | 290 | 20 | 24 | 25 |
| 20AA(3/4") | 184 | 464 | 290 | 21 | 26 | 26 |
| 25AA(1") | 184 | 464 | 290 | 22 | 26 | 27 |
| 32AA(1-1/4") | 222 | 464 | 290 | 24 | 28 | 29 |
| 40AA(1-1/2") | 222 | 468 | 290 | 26 | 30 | 31 |
| 50AA(2") | 254 | 576 | 360 | 39 | 43 | 44 |
■ Dedicated model codes are available for product selection. For details, please refer to the Selection Guide or Instruction Manual below.
■ A Calculation Data Sheet is available to calculate the required Cv value and valve travel for dedicated model selection.
※The Instruction Manual and Calculation Data Sheet can be downloaded from the links below.
※These documents are subject to revision. Please ensure that you use the latest version available from the download links.